DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-407CLSFY-PT (Call Classifier Port)

9
Tone Detection Verification Test (#42)
This test checks the operation of the TN744 in touc h-tone receiver, call classifier and R2-MFC modes. It verifies the circuit p ack’s ability to detec t DTMF, ring back, busy reorder an d modem answer tones and to g enerate and detect forward and backward MFC tones.
Table 9-172. TEST #42 Tone Detection Verification Test
Error
Code Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test
OR there was an internal system error.
1 ABORT The system could not allocate all the resources needed to test the tones.
1001 ABORT The system was unable to put the call classifier port in the appropriate
mode to test it.
1002 ABORT The system could not allocate time slots for the test c onnection. This
situation could occur when the system is heavily loaded. If the system is not
heavily loaded, then test the TDM-BUS via the test tdm command.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
network where the test aborted. If so refer to the recommended
procedures for TONE-BD or TONE-PT.
2. If a new Tone-Clock has been inserted, allow about 1-minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
2000 ABORT Call classifier circuit pack’s response to the test request was not received
within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2006 ABORT Indicates that the active Tone-Clock circuit pack or a Tone Detector circ uit
pack may not be functioning prop erly.
1. Test the
active
Tone-Clock circuit pack in the port network with the test
tone-clock UUC command and refer to the TONE-BD section for
failures.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page