DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-465DAT-LINE (Data Line Port)
9
FAIL The test failed because the data received did not match the d ata sent. This
would indicate that there is a fault somewhere in the transmit/receive path to
the TDM Bus, which will prob ably result in data corruption over this p ort. This
test may fail if the Maintenance/Test digital port used by the test is not
functioning properly.
1. Resolve M/T-DIG errors, if any.
2. Repeat Test #171.
3. If the test fails again, replace the data line circuit pac k.
PASS The port can correctly transmit/receive data. Investigate user-reported
troubles on this port usi ng other port tests and examining the ADU, external
wiring, and customer equipment.
Table 9-194. TEST #171 Digital Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page