DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-466DC-POWER (Single Carrier Cabinet Environment)
9
DC-POWER (Single Carrier Cabinet Environment)
DEFINITY Generic 3r systems support two different cab inet types: multicarrier
and single carrier. Single c arrier cabinets are used only for EPNs. Both cabinet
types may be powered by either AC or DC external power sourc e. Environmental
maintenance differs acc ording to cab inet type and external p ower supply. Refer
to the following table to dete rmine which maintenance ob ject documentation to
use for environmental maintenance.
MO Name As
It Appears in
Alarm Log Alarm
Level
Initial System
Technician Command
to Run1
1. UU is the universal cabine t number indicated in the PORT field of the alarm log.
Full Name of MO
DC-POWER MAJOR test environment UU Single Carrier Cabinet Environment
Cabinet Type Power
Source Environmental Maintenance Objects
Single carrier (EPN) AC or DC DC-POWER (all environmental
maintenance)
Multicarrier AC AC-POWER for AC-powered systems
(external power source)
POWER for AC-powered systems
(battery backup)
CARR-POW
(carrier port power supp ly)
CABINET
(temperature and fan sensors)
Multicarrier DC CARR-POW
(carrier port power supp ly)
CABINET
(temperature and fan sensors)