DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1126OPS-LINE (DS1 Off Premises Station Line)
9
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indic ate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
b. The DS1 OPS Line has been busied out by a busyout station <ext>
command. No calls c an be made on this line.
c. This error type indicates that t he circuit pack has b een removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interfac e circuit pac k.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors log ged
against the DS1 Interface circuit p ack. Look for DS1-BD/UDS1-BD errors
in the Hardware Error Log and follow the app ropriate procedures p rovided
in the DS1-BD/UDS1-BD (DS1/UDS1 Interface Circuit Pack) Maintenance
documentation.
Table 9-448. DS1 OPS Main t enance Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test station <ext>
15(a) Any Audit and Update Test
(#36)
18(b) 0 busyout station <ext> WARNING OFF release station <ext>
130(c) None WARNING ON test station <ext>
1281 Conference Circuit Test
(#7) MINOR ON test station <ext> l r 4
1537 NPE Crosstalk Test (#6) MINOR ON test station <ext> l r 3
1793(d) test board UUCSS l