DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-94ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Table 9-37. TEST #48 Station Present Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp to determine the station’s extension.
Enter status station extension to determine the service state of the
port. If the port is in use, it will be unavailable for certain tests. Wait
until the port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
3. Check for phone left off-hook or for wiring problems.
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait until the port
is idle before retesting.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
3. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
1008 ABORT Could not allocate a ringing circuit for one of the following reasons: (1) all
the ringing circuits are in use, or (2) the ringing generator is defective, or
(3) it is not wired correctly.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log.
If an ABORT 1008 occurs for Test #48 on other circuit packs as well,
then the ringing generator may be defective or not wired correc tly. If it
does not occur on other ports, then that circuit pack is c urrently using
all four ringing phases.
Continued on next page