DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1291PMS-PRNT/JNL-PRNT (PMS Printer Link)
9
Error Log Entries and Test to Clear Values
Notes:
a. Craft busied out the Journal Printer Link. The link is torn d own. Enter
release command to restore the link.
b. Link Retry Test (#215) fails. Physical link cannot be set up, usually
because of hardware prob lems such as power off or c able disconnec t.
Refer to “Procedures for Restoring the PMS Printer Link” above.
c. Physical link cannot be set up, usually because of hard ware problems
such as power off or cab le disconnect. The PMS Printer Link physical link
is down due to the following causes: cable to the p rinter device is
disconnected , the printer device is p owered off, or the data extension
where the printer device c onnects to has been bus ied out. Check the
connectivity of wire and c able among wall jacket , data module, and the
printer device. Enter status data <extension> and verify that the data
extension of the printer device is in the in-service/idle state. If the d ata
extension is not available, then refer to the ‘‘Procedures for Restoring the
PMS Print er Lin k’’ ab ove.
d. Link idle timer; link come s down. This indicates that the p rinter device is in
an off-line state, for example, paper jam or paper out. Check the p rinter
device and ac t promptly to put it b ack to on-line state. Enter test journal
wakeup-log|pms-log command to set up the p rinter link.
Table 9-507. PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures. Both PMS Printer and Journal
Printer are administered to the same extension, and the printer is not connected. Refer to the
Procedures for Restoring the PMS Printer Link
above for resolution.
0 Any Any Any test journal
wakeup-log|pms-log sh
18 (a) 0 busyout journal
wakeup-log/pms-lo g WARNING OFF release journal
wakeup-log|pms-log
257 (b) Any Link Retry Test(#215) MINOR/2
WARNING
2. Minor alarms may be down graded to Warning al arms based on the value used in the set options
command.
OFF test journal
wakeup-log|pms-log l
513 (c) Any test journal
wakeup-log|pms-log
769 (d)