DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-954ISDN-SGR (ISDN-PRI Signaling Group)
9
3 FAIL Both the primary and secondary are down.
1. Examine the results of the Primary and SecondarySignaling Link Hardware
Tests (#636 and #639) and follow recommendations provided there.
2. If tests #636 and #639 pass, the Layer 2 Query test may still fail if the
Signaling Channel at the far end has not been administered correctly or if
the Signaling Channel has been busied out. Verify that the Primary and
Secondary Signaling Channel (D-channel) at the far end has been
administered correctly. Verify that the DS1 port used for the Primary and
Secondary D-channels has not been busied out at the far end.
PASS The Primary Signaling Channel is up and, if administered the Secondary
Channel is up.
Table 9-365. TEST #647 Layer 2 Status Query Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page