DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1611SYSAM (Circuit Pack)
9
Time-Of-Day Clock Test (#913)
The short term accuracy of the tim e-of-day clock is tested . The test reads the
clock once, waits 10 sec onds, and then read s the clock again. The sec ond
reading of the clock must be within certain limits (10 sec onds) relative to the first
reading for the test to pass. The display ti me command can b e used to disp lay
the current setting of the time-of-day c lock.
If the time-of-day clock is n ot functioning correc tly, the software time-of-day clock
is used (this clock is not as accurate as the hardware clock).
FAIL Internal System Error
1. Retry the command
PASS The SYSAM c ircu it pa ck has been sent t he co rrect state for th e syste m LEDs.
If the LEDs do not reflect the system alarms shown in the alarm log, the
SYSAM circuit pack may have problems.
1. Veri fy the LEDs on the SYSAM c ircu it pa ck c an be chang ed b y iss uing
the test led port-network 1 command. A ll the SYSAM circuit pack LEDs
should go on and then off, and then be refreshed.
2. After the test led port-network 1 command finishes, if the SYSAM circuit
pack LEDs do not reflect the alarm log, follow normal escalation
procedures.
Table 9-609. Test #913 Time-Of-Day Clock Test
Error
Code Test
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
Continued on next page
Table 9-608. Test #912 SYSAM Refresh Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page