DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-415CO-DS1 (DS1 CO Trunk)

9
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected time slot and never crosses over to time slots rese rved for other connections. If the NPE is not working correctly, one-way and noisy connec tions may be observed. This test is usually only pa rt of a port’s Long Test Sequence and takes about 20 to 30 seconds to c omplete.
Table 9-175. TEST #6 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use th e status trunk command to
determine the servic e state of the port. If the p ort is in use, wait until the
port is idle before testing.
2. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1001 ABORT System resources require d for this test are not availab le.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. The status health command can be used to determine if
the system is experiencing heavy traffic.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some tone
detectors may be out-of-service. The list measurements tone-receiver
command will disp lay information on the system’s tone re ceivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page