DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-416CO-DS1 (DS1 CO Trunk)
9
1004 ABORT The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status trunk command to
determine the servic e state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1020 ABORT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources req uired for this test are not available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2053 ABORT At least one of the following errors was found on the DS1 circuit pack: loss
of signal (1281), blue alarm (1793), red alarm (2049), yellow alarm (2305),
or hyperactivity (1537).
1. Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Table 9-175. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page