DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-10Common Abort and Fail Codes
8
Common Abort and Fail Codes
Table 8-3 lists common error codes assoc iated with abort and fail results for
busyout, release, test, and reset comm ands. In addition to these, m any
maintenance objects have o ther unique error codes.
Table 8-3. Common Error Codes for Busyout, Release, Test,
and Reset Commands
Error
Code Command
Result Description/Recommendation
ABORT System resources are unavailable to run c ommand.
1. Try the command again at 1-minute int ervals up to 5 times.
0 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT A DS1 interface circuit pac k could not b e reset because it is
currently supplying the on-line synchronization referenc e.
1. Use the set sync command to designate a new DS1
interface circuit p ack as the on-line reference, then try the
reset again.
1010 ABORT Attempt was made to busyout an ob ject that was already busied
out.
1011 ABORT Attempt was made to release an ob ject that was not first busied
out.
1015 ABORT A reset of this circuit pac k requires that all maintenanc e objects
on it be in the out-of-service state.
1. Use the busyout board command to place all objects on the
circuit pack in the out-of-service state, and try the reset
again.
1026 ABORT The specified TDM bus can not be busied out b ecause the
control channel or system tones are b eing carried on it. You can
use the set tdm PC command to switch the c ontrol channel and
system tones to the other TDM bus.
1030 ABORT This command is not allowed on a c ircuit pack on the standby
SPE.
Continued on next page