DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1174PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)
9
Table 9-467. TEST #175 Data Module Internal LoopAround Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may be in
use on a valid call. Use status data-module to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Loop around testing is not enabled on the data module administration form.
1. Set ‘‘Loop-Around Test’’ field to ‘‘y’’ on the data module administration form.
1042 ABORT The port under test is a TTI port and thus has only default translations and no
assigned extension. The test requires an extension assigned to the port being
tested.
1. If there is a need to execute the test on this particular port, then you must
fully administer the port so that is has an assigned extension.
1180 ABORT A Maintenance/Test Circuit pack digital port is not available to carry out the
test.
1. Check to see if the Maintenance/Test digital ports are present (use the list
config board command and look for ports 02 and 03).
2. If the digital ports (02 and 03) on the M/T-BD are not present, refer to the
"M/T-DIG (Maintenance/Test Digital Port)" section.
3. If the digit al ports are present, try the c ommand again at 1-minute i ntervals
up to 5 times.
1181 ABORT No time-slots available to connect digital ports for the test.
1. Try the command again at 1-minute intervals up to 5 times.
1182 ABORT Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1340 ABORT No Maintenance/Test dig ital port is currently availab le to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. Because at least one Maintenance/Test circuit pack must always
be present in the PPN of any G3r system, there should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determ i n e why no po r ts appear i n the list config display. Refer to "M/T-DIG
(Maintenance/Test Digital Port)" and M/T-BD maintenance documentation.
2. Look for M/T-DIG errors in the Error Log. If present, refer to M/T-DIG
maintenance doc umentation.
3. If the ports are present and no errors are logged against them, retry the
command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
Continued on next page