9-1560SW-CTL (Switch Control)

9
interchange. In that case, Error Types 2 and 150 will b e entered in the error log for th e Switc h Con trol o n the s tand by SPE, i ndic atin g tha t a fai lure o f the Sw itch Contr ol Transm issio n Test ca used a spo ntan eous SPE i nterc hang e. Refe r to th e Error Log information presented earlier in this repai r document for the procedures to clear p roblems associated with a SW-CTL error log entry of 2.
Table 9-593. TEST #94 Control Channel Transmission Test
Error
Code Test
Result Description/ Recommendation
0 ABORT The port circuit packs necessary for this test are not available. For this test to
pass, it must receive a successful response to a circuit pack query message
from at least one of the following circuit pack types in the PPN cabinet:
Tone/Clock circuit pack (TN768 or TN780) Tone Detector circuit pack (TN599)
1. Retry the command at 1-minute intervals a maximum of 5 retries.
2. If the test keeps aborting with this abort cod e, replace the MSSNET circuit
pack.
3. If the test keeps aborting with this abort cod e, verify that the PPN has at
least one of the circuit packs listed above.
1335 ABORT Internal System Error. The MSSNET circuit pack is on the standby SPE and this
test is not allowed to execute on a MSSNET circuit pack on the standby SPE.
1. If this abort c ode is received for a Switch Control on a standb y SPE in a
system equipped with the High Reliability or Critical Reliability configuration,
there must be a software error. Test #94 is not allowed to run on a standby
Switch Control.
2. Retry the command at 1-minute intervals, a maximum of 5 times.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused b y a planned interch ange initiated automatic ally during 24
hour scheduled testing.
1. Wait 3 minutes and retry the command.
2012
2500 ABORT Internal System Error
1. Retry the command.
2013
2100
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 retries.
Continued on next page