DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-60change system-parameters maintenance
8
Scheduled Maintenance
A series of maintenance tests and op erations runs automatically every day
according to the schedule and settings specified in Table 8-7
Test Remote
Access Port Specifies whether testing of the remote ac cess port on the SYSAM
circuit pac k is enabled. This field should b e set to "yes" whenever
there is an INADS line connected to the swit ch and there is a
maintenance contract in ef fect so that alarm origination cap ability
is maintained.
If no equipment is connec ted to the remote access p ort, or if a trunk
for remote access and alar m origination is not provided , running
tests on the remote acc ess p ort on the SYSAM resul ts in t est fai lures .
This causes unnecessary maintenance alarms and allows
potentially destruc tive tests to be run. Setting this field to “ no”
prevents this.
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) at which the
Customer-Provided Equipment (CPE) alarm is activa ted. If the level
is ‘‘none,’’ the CPE does is not activated for any alarm. (no ne)
NOTE:
The CPE alarm is always activated when the switch g oes into
Emergency Transfer, regardless of the CPE Alarm Activation
Level setting.
Customer
Access to
INADS Port
Provides the capability to prohibit access to s ystem administration
and maintenance interface, via the INADS port when using
customer login ID’s. This field c an only be activated Lucent through
system-parameters maintenance ad ministration.(no)
Table 8-7. Schedules and Settings for Maintenance Tests
Start Time The hour and minute in 24-hour notation at which d aily scheduled
maintenance will begin running .
Stop Time The hour and minute when scheduled daily maintenance will stop
running. If any daily maintenanc e operations are not comp leted by this
time, the system will note where in the sequenc e it stopped and
perform those operations dur ing the next scheduled daily
maintenance.
Daily
Maintenance This display-only field simp ly represents the series of tests that are
always run by maintenance software as p art of daily maintenance.
Continued on next page