DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1621SYSAM (Circuit Pack)
9
Table 9-613. TEST #912 SYSAM External Modem Present Test
Error
Code Test
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
1018 ABORT The test has been disabled by administration.
1. To enable test, set the Test Remote Access Port field to y on the
system-parameters maintenance screen.
2. Retry the command.
1049 ABORT External modem is not administered. When using an active TN1648 (prior to
suffix B), this abort code is normal, because only this test only applies to
external modems.
1318
1335
2029
2033
2500
ABORT Internal system error
1. Retry the command.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused by a planned interchange initiated automatically during
24 hour scheduled testing.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby SYSAM circuit pack in the standby SPE
carrier because the standby SPE is unavailable.
1. Refer to the ‘‘STBY-SPE (Standby SPE Maintenance)’’ documentation for
information on why a standby SPE may be unavailable and what repair
actions should be taken. The screen for the status spe command s hould
indicate that handshake is down. This may be caused by a variety of
reasons such as the SPE-SELECT switches on the DUPINT circuit packs
being set to the position of the active SPE, a failure of the DUPINT circuit
pack, or loss of power on the standby SPE. The SPE selected field on
the status spe screen displays spe a or spe b if both SPE- SELECT
switches are in the a or b positions, respectively.
1364 ABORT The component on which the test was to be run is on the Standby SPE. This
test may only be run on this component when it resides on the Active SPE.
1. To verify the remote access line is working (connected), run this on the
Activ e SYSAM.
Continued on next page