DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-526DIOD-DS1 (DS1 DIOD Trunk)

9
Port Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the DS1 Interface circuit p ack to assure that the trunk’s translation is c orrect. Translation updates includ e the following data: trunk typ e (in/out), dial type, timing parameters, and signaling bits enabled. The port audit operation verifies the consistency of the current sta te of trunk kept in the DS1 Interface circ uit pack and in the switch software.
1020 ABORT The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the c ircuit pac k.
PASS The port can correctly conference multiple connec tions. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
Table 9-214. TEST #7 Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page