DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1597SYS-PRNT (System Printer)
9
Error Log Entries and Test to Clear Values
Notes:
a. The System Printer Link has been busied out.
b. A failure was encountered while att empting to set up the System Printer
Link. This attempt could have b een initiated by either Report Sched uler
software or by link maintenance d uring automatic link retry or as a result of
a Link Retry Test (#215) request. The Aux Data field indicates the
following:
Refer to the preceding sec tion ‘‘Procedures for Restoring the System
Printer Link for recommended maintenanc e strategy.
c. The SYS-PRNT wa s inte rrup ted f or on e of th e foll owin g rea sons:
The ca ble t o the SYS-PRNT out put d evic e is disc onne cted
The SYS-PRNT o utpu t de vice is po wered off
The data extension to which the SYS-PRNT output device connects
has been busied out
Internal software error
Table 9-601. SYS-PRNT Maintenance Error Log Entries
Error
Type Aux Data Associated Test Alarm
Level On/Off
Board Test to Clear
Value
0 0 Any Any Any test sp-link
18 (a) 0 busyout sp-link WARNING OFF release sp-link
257(b) 1, 3 4, 5, 6 Link Retry Test (#215) MINOR/1
WARNING
1. Minor alarms may be downgraded to Warning alarms b ased on the value u sed in the set
options command.
OFF test sp-link l
513 (c) 0 None MINOR OFF test sp-lin k
1 No system port available. Refer to PDATA-PT for explanation.
3, 4 Time-out during setup attempt. Most likely due to problem with physical
link or printer status.
5 Internal system error. Most likely temporary/sporadic failure.
2, 6 The data module the printer is trying to use is busy with another call. Use
the Status data module command to determine when the port is
available for testing.