9-1092MODEM-PT (Modem Pool Port)
9
1340 ABORT No Maintenance/Test digital po rt is currently availabl e to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. Because at least one Ma intenance/Test circuit pac k must always be
present in the PPN of any G3r system, there should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determine why no ports appear in the list config display.
2. If the ports are present and no errors are logged against them, retry the
command at 1 minute intervals a maximum of 5 times.
3. If the test continues to abort, replace the Maintenance/Test circuit pack.
2004 ABORT Off-Hook was not received from the Pooled Modem.
1. Busy-out the digital port being tested on the Pooled Modem circuit pack.
Retry the command at 1 minute intervals a maximum of 5 times.
2. If the test still aborts, replace the circuit pac k.
2005 ABORT The Maintenance/Test Board digital port and the Pooled Modem Board digital
port failed to handshake.
1. Retry the command at 1 minute intervals a maximum of 5 times.
2. If the test still aborts, replace the Pooled Modem circuit pack.
2312 ABORT The Looparound Test did not complete, failed to receive loop-back data.
1. Retry the test, if still aborts, replace the Pooled Modem Board.
2313 ABORT The Maintenance/Test Board digital port allocated for this test did not respond to
downlinked messag e .
1. Retry the command at 1 minute intervals a maximum of 5 times.
2. If the test continues to abort, replace the MTB.
2314 ABORT The Modem Pool digital port did n ot res pond to downlinked message. This error
is internal to the Modem Pool circuit pack and does not involve external
equipment or interfaces.
1. Busy-out the TN758 Pooled Modem conversion resources on the circuit
pack.
2. If the test continues to abort, replace the Pooled Modem circuit p ack and
retest.
2500 ABORT Internal system error.
1. Retry the command at 1 minute intervals a maximum of 5 times.
Table 9-433. TEST #98 Modem Pool Conversion Resource
Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page