DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Additional Maintenance Procedures
6-42Automatic Transmission Measurement System (ATMS)
6
Running ATMS Tests(Test Analog-Testcall Command)
ATMS test calls can be originated either on d emand or accord ing to the ATMS
Test Schedule. Test schedules are set up with test-schedule commands which
are described in

DEFINITY Enterprise Communications Server Release 5.4

Administration and Feature Description

.
Demand test calls are orig inated by the test analog-testcall command. You can
specify testing of an entire trunk group, an individual trunk, or all trunks on a
single circuit pa ck. Trunks can be addressed b y either group/member n umbers
or circuit pack/p ort locations. The type of test call, the n umber of the testing line
on the far-end switch and v arious other parameters must be ad ministered on the
trunk group form before the c ommand can execut e.
Table 6-7. ATMS Administration
Form Field Entry/Remarks
System-parameters
customer options ATMS? y (You must logoff/login in order for
changes on this form to take effec t.)
Station Extension At least one TN711 analog port must
be assigned.
Port Nu mber UUCSS01 where UUCSS is the
location of any TN771
Port Typ e COR 105TL
The number of a COR that has
testing enabled (see next form )
Class of Restriction Facility Access Trunk Test y
Trunk Group Maintenance Tests?
ATMS Thresholds (page 4
of form)
y
This page is used to spec ify
performance thresholds, the t ype
and access numb er of the far-end
TTL, and system response to test
failures.
Hunt Group (Optional, for incoming test calls) If
the system has several TN771s, you
can use this form to make up a hunt
group of TTLs so that one extension
can be used for the whole p ool.
ATMS Trunk Test
Sched ule (Optional) To set up a test schedule,
see Chapter 4 of

Generic 3 V2

Implementation,

555-230-653
.