DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1338PRI-CDR/SEC-CDR (Call Detail Recording Link)
9
Error Log Entries and Test to Clear Values
Notes:
a. The CDR link is busied out. The CDR link is torn down.
b. Link Retry Test (#215) fails. An error was detected when setting up the link.
Refer to the preceding sec tion ‘‘Procedures for Restoring the CDR Link’’
for resolution.
c. The CDR physical link is down for one of the following reasons:
Cable to the CDR output devic e is disconnected.
CDR output device is powered off.
The data extension where the CDR output device c onnects to has
been busied out or there is a sc heduled daily interc hange.
Check the connectivity of wire and cable among wall jac ket, data module,
and the CDR output device . Enter status data extension and verify that
the data extension of the CDR output devic e is in the in-service/idle state.
If the data extension is not available, then refer to The preceding section
‘‘Procedures for Restoring the CDR Link’’ for resolution. Issue the display
system-parameters-maintenance command to see the star t time of daily
maintenance. If the error occu rs and is resolved during of daily
maintenance, it can be ig nored.
Table 9-523. CDR Link Maintenance Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test S equence first. If all tests pass, run the Long Test S equence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test cdr primary|second ary
sh
18(a) 0 busyout cdr
primary|secondary WARNING OFF release cd r
primary|secondary
257(b) Any Link Retry Test (#215) MINOR/2
WARNING
2. Minor alarms may be down graded to Warning alarms b ased on the value used in th e set options
command.
OFF test cdr primary|secondary
l
513(c) test cdr primary|secondary
1025(d)
1281(e) Any