DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1376SN-CONF (Switch Node Configuration)
9
i. The SNI is connected to a DS1C, but no DS1C is administered .
To resolve this error, refer to FAIL code 140 for test 759.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below whe n
inspecting errors in the sys tem. By clearing error cod es associated with the
Configuration Audit
for example, you may also clear errors g enerated from other
tests in the testing sequenc e.
Configuration Audit (#759)
This test is non-destructive.
NOTE:
For descriptions of result cod es for this test refer to:
SNC-BD when the circuit pack tested is a Switch Node Clock (c ircuit pack
slots 10 or 12).
SNI-BD when the circuit pack tested is a Switch Node Interface (c ircuit
pack slots 2-9 or 13-20).
This test is run via the test board short or test board long command for SNI
circuit packs or SNC circ uit packs.
For SNI circuit packs, this test queries the SNI for SNCs in the same switch node
carrier, SNI peers, DS1Cs, and EI or SNI neighbors that the SNI c an
communicate with and c ompares this data to the ad ministered data.
For SNC circuit packs, this test queries the SNC for SNCs and SNIs in the same
switch node carrier that the SNC ca n communicate with and c ompares this data
to the administered data.
Failures of this test cause entries in the error and alarm log s against Switch Node
Configuration (SN-CONF) with the board location of the SNI or SNC.
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Configuration Audit (#759) X X ND
Processor Route Audit (#760) X ND