9-50ANL-16-L (16-Port Analog Line)
9
Table 9-21. TEST #7 Conference Circuit Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s ex tension.
Enter status station extension to determine the service state of the
port. If the port is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018 ABORT The test has been disabled via administration. The default for the Test field
on the station form is y. Determine why this field has been set to “n” on this
station (this may be due to the ringing application Test #48, which can be
customer or terminal disturbing).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test? field on the station to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Resolve any TONE-PT errors.
2. Resolve any TONE-PT errors.
Continued on next page