DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-507DIG-LINE (Digital Line)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exist, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test.
1. Enter display port UUCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the port is in use, wait until the
port is idle before resetting. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT The installed circuit pack does not support this operation.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT System resources required to run this test are not available.
1. Make sure terminal is connected and repeat test.
2. If test fails replace terminal and repeat test.
3. Retry the command at 1-minute intervals a maximum of 5 times.
14 FAIL The primary ch annel is not operating prope rly. User impact may range from
noticing nothing to not being able to use the port. Check the results of "Voice
and Control Channel Local Loop Test (#13). If that test fails, suspect the Digital
Line circuit pack. If that test passes then replace the terminal. If both tests fail,
and component replacement does not chang e the results, then:
1. Run circuit pack tests to check the tone generator circuit pack and the
Tone Detector circuit pac k using test board UUCSS .
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
1015 ABORT The station is not busied out (busyout station).
Table 9-206. TEST #1201 Digital Terminal Remote Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page