DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-659DS1-FAC (DS1 Facility)
9
Failure Audit (#949)
This test is non-destructive.
This test queries the DS1 CONV circuit pack for any existing circuit pack or
facility failures and any unackno wledged cleared failure messages. Upon
receiving the query req uest, DS1 CONV firmware sends failure reports to the
maintenance software for every error in its failure d atabase.
This test operates on both maintenance ob jects DS1C-BD and DS1-FAC. Error
counts of both MOs (DS1C-BD and DS1-FAC) that are displayed in the error log
will be incremented when this tes t is executed. This test is executed via the test
board command. The test is also executed internally by the maintenance
software when an alarm is resolved
Table 9-259. TEST #949 Failure Audit
Error
Code Test
Result Description/ Recommendation
2100 ABORT Could not allocate the necessary syst em resources to run this test.
2000 ABORT Timed out while waiting for a response from the circuit pack.
2300 ABORT The downlink message necessary to run this test could not be sent.
2301 ABORT The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2316 ABORT Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
FAIL The DS1 CONV circuit pack reported failures or retransmitted a cleared failure
message.
1. Enter display errors and follow the associated repair procedures for any
DS1C-BD and DS1-FAC errors.
PASS The DS1 CONV circuit pack has no failures.
Continued on next page