DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-112ANN-BD (Announcement Circuit Pack)
9
FAIL The ANN-BD may be defective or the active tone-clock circuit pac k in the
same PN may be bad. Announc ements recorded or played b ack while the
clock circ uitry is not functioning p roperly sound d istorted.
1. Reset the Announcement circuit pack via the reset board UUCSS
command and then run this test again. If the test continues to fail,
proceed to Step 2 or 3, whichever applies.
2. If this PN has duplicated Tone-Clocks: Determine the Active TONE-BD in
this PN via the status port-network 1 command. Make the Standby
Tone-Clock circuit pack active via the set tone-clock UUC command.
Rerun the test. If the test passes, then replace the now Standby
Tone-Clock circuit pack. If the test continues to fail, replace the ANN-BD
circuit pack.
!CAUTION:
Replacing the announcement circuit pack results in loss of integrated
announcements. See Essential Service Information. See “TON E -BD” for
Tone-Clock replacement instructions.
3. If the PN has a single tone-clock: Replace the ANN-BD. Rerun the test. If
the test continues to fail, replace the Tone-Clock circuit pack located in
the same PN as the ANN-BD.
!CAUTION:
Replacing the PPN Tone-Clock circuit pack in a Standard Reliability
system (simplex SPE) will cause COLD 2 reset (servic e outage).
Replacing a simp lex EPN Tone-Clock will cause an EPN reset with
service outage to that EPN. See How to Replace a Tone-Clock Circuit
Pack in the “TONE-BD” section of this chapter. Replacing the ANN-BD
will result in loss of integrated announcements. See Essential Service
Information.
4. If failures of this test continue to raise alarms, replace the circuit pack
even if the previous steps were successful.
PASS Announcement playbacks must have clear sound quality. Investigate
user-reported troubles on this circuit pack using the other circuit pack and
port tests. Refer to “ANN-PT” for descriptions of the port tests.
Table 9-43. TEST #212 Clock Match Inquiry Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page