DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1390SNC-BD (Switch Node Clock Circuit Pack)
9
Table 9-550. TEST #759 Configuration Audit
Error
Code Test
Result Description/ Recommendation
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2306 ABORT The SNC circuit pack is not responding to test req uests sent by software.
1. Run the test led switch-node for the switch node that this board resides in
to verify whether the LEDs on the board light.
2. If the LEDs on the other boards in the carrier light, but the LEDs on this
board do not light, run test 760 via test board UUCSS l for the active SNC
in this carrier. Wait 5 minutes and then try step 1 one more time. If the LEDs
on this board still do not light, replace this board. Replacing an SNC may
be service interrupting. Refer to the SNC-BD section for the procedure for
replacing an SNC.
3. If none of the LEDs light for the boards in the same carrier as this board, fix
any problems associated with the connectivity of this carrier to the SPE.
Check list fibers to determine the fiber connections to this carrier. Check
the LEDs on all SNIs and EIs and fix any fiber problems. Enter display
errors and follow the associated repair procedures for any EXP-INTF error
entries associated with the PPN. Also, follow the associated repair
proc edures for any SYNC, SNI-B D, SNC-BD , FIBER-LK, or SNI-PEER er ror
entries.
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page