Maintenance Object Repair Procedures
9-1914VC-DSPPT
9
Error Log Entries and Test to Clear Values
Notes:
a. This port has been busied out by the busyout port UUCSSpp command.
b. The VC DSP Por t NPE Cro sstal k Test(#1 103) faile d.
c. The VC DSP Port Local TDM Loopback Test(#1104) failed. Run the Long
Test Sequence.
d. A critical hardware fai lure has been detected on the circuit pac k. Reset
the port by the busyout port UUCSSpp and rese t port UUCSSpp
commands. If the VC Reset DSP Test (#1106) passes, then the on-board
circuitry is healthy. Retire the alarm with the test port UUCSSpp long
clear command.
e. The VC DSP port reported loss of framing on the Service Channel between
the VC and MMI circuit pac ks.
f. The VC DSP Port DSP Loop bac k Test ( #1105 ) fai led.
g. The DSP corresponding to this por t on the VC circuit pack rep orted a
firmware error. No action is required.
Table 9-706. VC-DSPPT Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/ Off
Board Test to Clear Value
01
1. Run the short test sequence first. If all test pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp sh r 1
18 (a) 0 busyout port UUCSSpp WNG OFF release port UUCSSpp
257 (b) Any NPE Crosstalk Test (#6) MIN ON test port UUCSSpp 1 r 3
513 (c) Any VC DSP Port Local TDM
Loopback Test (#1104) MIN ON test port UUCSSpp sh r 3
778 to
781 (d) Any VC Port Reset DSP Test
(#1106) MAJ ON See note (d)
1025 (e) WNG ON
1281 (f) Any VC DSP Port DSP
Loopback Test #(1105) MIN ON test port UUCSSpp sh r 3
3840 (g)