DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-355test packet-interface
8
test packet-interface
test packet-interface [CSS] [short | long] [repeat # |clear] [schedule]
This command performs hard ware diagnostic tests on any or a ll of the packet
interface circuit p acks in a specifi ed carrier. Tests performed inc lude local
memory checksum tests, loop -around tests, and chec ks of failure counters.
The Maintenance Loop-Around Test (#886) is included in the test sequences of
active
packet-interface c ircuit packs only. The Active-Standb y Peer Link Test
(#888) is included in the tes t sequences of the
standby
packet-interface circuit
packs only.
If the packet-interface c ircuit pack is in the “ out-of-service” or “uninstalle d”
states, no demand tests as well as s cheduled, pe riodic and error tests will run.
See also reset packet-interface and status packet-interface.
Parameters
CSS The cabinet is always 1 and need not be entered. The carrier, a or b, must b e
enter ed on ly for dup lica ted SPEs . Slot n umbe r rang es fr om 1 to 3,
corresponding to the dedicated PKT-INTFC slots on the control carrier. If
omitted, all Packet Interface circ uit packs on the sp ecified carrier are tested .