DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1057MIS (Management Information System)
9
MIS (Management Information System)
The Management Information System (MIS)/Call Management System (CMS)
maintenance object is use d only to monitor MIS busyouts during administration
of MIS translations. There are no hardware failures associated with this MO.
The MIS/CMS is an adjunct processor that collec ts Automatic Call Distribut ion
(ACD) data sent from the switch. In orde r to change MIS translations, a switch
administrator must first enter a busyout mis command at the G3-MT. When the
MIS is busied out, the switch will stop sending ACD data to the MIS, and a
Warning alarm will be raised.
When the switch administrator is finished , a release mis command should be
entered at the terminal. This will clear the Warning alarm and allow the switch to
send ACD data to the MIS.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run Full Name of MO
MIS WRN release mis Management Information System
Table 9-420. Management Information System Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear
Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any release mis
182
2. When the busyout MIS command is is sued, no data is sent to the MIS/CMS regard less of the
link state. To allow data to be sent to MIS/CMS, a release mis command must be issued from
the terminal.
0 busyout mis WARNING ON release mis