DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1777TIME-DAY (Time of Day)
9
3. Test the a ctiv e TN164 8 SYSAM c ircu it pa ck us ing t he test maintenance [a
| b] sh command. If any tests fail, refer to the rep air procedures for the
SYSAM circuit pack before further investig ating time-of-day prob lems. If
all tests PASS and the alarm has not been retired, proceed to Step 4.
4. Repla ce th e act ive TN1 648 SYSAM circ uit p ack must b e rep lac ed. Se e
"Replac ing SPE Circ uit Pac ks"
in Chapter 5. The alarm should b e resolved
withi n 15 mi nutes of rep lac ing t he SYSAM a nd re setti ng th e time with set
time.