DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1558SW-CTL (Switch Control)

9
messages to or from port circ uit packs. This test will not affect estab lished calls but call setup may b e affected for several second s.
Table 9-592. TEST #93 Switch Control Reset Test
Error
Code Test
Result Description/ Recommendation
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
This may be caused by a planned interchange initiated automatically during 24
hour scheduled testing.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby Switch Control on the MSSNET circuit
pack in the stand by SPE carrier because the stand by SPE is unavailable.
1. Ref er to th e STBY-SPE mai ntenan ce do cumen tation for in format ion on w hy
a standby SPE may be unavailable and what repair actions should be
taken. The screen for the status spe command should indicate that
handshake is down. This may be caused by a variety of reasons such as
the SPE-SELECT switches on the DUPINT circuit packs being set to the
position of the active SPE, a failure of the DUPINT circuit pack, or loss of
power on the standby SPE. The
SPE Select ed
field on the status spe
screen will display
spe a
or
spe b
if the SPE-SELECT switches are in the a
or b positions, resp ectively.
2000 ABORT Response to the test request was not received within the allowable time period.
If the system is equipped with the High Reliability or Critical Reliability
Configuration and if the MSSNET circuit p ack is on the standby SPE, this abort
code may indicate that the standby SPE is not responding to the handshake
message. If this is the case, the standby SPE maintenance software may take
up to two minutes to indicate that handshake communication with the standby
SPE is down. The ABORT code will then change to 1339 (standby SPE
unavailable).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2012 ABORT Request for results timed out.
2500 ABORT Internal System Error
1. Retry the command two times.
2013
2100
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 retries.
2334 ABORT The hardware mailbox in the standby Duplication Interface circuit pack is not
ready to receive messag es.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page