DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-663DS1 CONV-BD
9

Figure 9-34. DS1 CONV Complex in Duplicated PNC with 1 SN

DS1 CONV Administration and Board Insertion

Board insertion is the detec tion of a circuit pac k by the system. The DS1 CONV

circuit pack will n ot be inserted unless the circ uit pack type, TN574 or TN1654, is

entered into the associated field in circuit pac k administration screen. The Fiber

Endpoint (the EI or the SNI) must also be inserted and be operational for the DS1

CONV circuit pack to func tion.

Fiber link administration must be c ompleted before the DS1 CONV maintenance

can be operational. Fiber links are ad ministered via the add fiber-link command.

Fiber Endpoints, DS1 CONV circuit pack loc ations and DS1 facility options are

entered as a part of the fiber link administration.