Maintenance Object Repair Procedures
9-90ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Table 9-36. TEST #47 Loop Around and Conference Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
7 ABORT The port was seized by a user for a valid call.
1. Enter display port UUCSSpp to determine the station’s extension.
Enter status station extension to determine the service state of the
port. If the port is in use, it will be unavailable for certain tests. Wait
until the port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5
times.
1000 ABORT System resources required to run this test were not availabl e. The port may
be busy with a valid call. (This could be a Music-on-Hold port.)
1. Enter display port UUCSSpp to determine the station’s extensio n.
Enter status station extension to determine the service state of the
port. If the port is in use, it will be unavailable for certain tests. Wait
until the port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5
times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-ser vice.
1. Resolve TTR-LEV errors.
2. Resolve TONE-PT err ors .
3. If neither condition exists, retry the test at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port has been seized for a valid call during the conference or noise
test.
1. If the circuit pack is a TN742 of Vintage 10 or less, this test is not valid.
Otherwise, proceed with step 2.
2. When the port is available for testing, retry the command at 1-minute
intervals for a maximum of 5 times.
Continued on next page