DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1329PPP-PT (Control LAN Packet/Port)
9
tone receiver receive tones on another timeslot. The tones are looped through the
ppp port.
Test failure indicates failure of the
CLAN (TN799) circuit pack
TDM Bus
Tone generator / tone receiver circuit pac k
If the received tones: Then:
Match the tones sent The test passes
Do not match the tones sent The test fails
Table 9-518. TEST #1285 TDM Looparound Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT The port is in use.
1. Determine port status (status clan-port UUCSSpp).
2. If port is idle, retry the TDM Looparound Test (#1285).
3. If port is not idle, busyout the port (busyout port UUCSS).
1002 ABORT No TDM bus timeslots available fo r the test.
1. Retry the command at 1-minute intervals, up to 5 times.
1003 ABORT No more tone receivers idle for use in this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS
and reset board UUCSS).
2. If the problem persists, replace the circuit p ac k.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
Continued on next page