Notes:
a. The circuit pack stop ped functioning or is physically removed from the
system.
NOTE:
This alarm logs approximately 11 m inutes after removing the circuit
pack and/or the SAKI Sanity Test (#53) fails.
If the circuit pac k is not in the system, insert a circuit p ack in the same slot
as the error indicates. See note (g).
b. Transient communication problems b etween the switch and this c ircuit
pack. Execute the test board UUCSS command and refer to the repair
procedures for the Control Channel Loop Around Test (#52).
c. On-board hardware failure. Aux data values correspond t o the following
detected errors:
1795 (i) 46085 MINOR ON
2305 (j) 46104 None ON
2306 (i) 46081 None ON
3330 (j) 46083 MINOR OFF
3586 (k) MINOR OFF
3840(l) 4096
to
4101
3842 (m) 46095
3843 (n) 46097
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error
Table 9-625. TBRI-BD Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page