DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Architecture
1-9How to use the Maintenance book
1
Screen 1-4. Test Results screen
15. Find the Port Diagnostic Test (#35) [from the Test No. field) in the
DID-TRK section of the Maintenance book. Note the Error Code
(61472).
16. Look in Table 1-3 for Test #35 and then find “61472” in the Error Code
column
and
“FAIL” in the Test Result column read the
Description/Recommendatio n column.
17. Perform both steps in the Desc ription/Recommendation colu mn.
18. Test the port (test port 01C1008 long and press Ent er.) again after all of
the recommendations are exhausted.
19. If all tests pass, wait app roximately 3-5 minutes for the Alarm and Error
logs to clear.
20. Type display alarms and p ress Enter twice.
21. Check that the DID-TRK alarm does not app ear in the log.
Field descriptions
Table 1-3. TEST #35 Port Diagnostic Test
Error
Code Test
Result Description/Recommendation
61472 FAIL Battery feed test failed. A problem with the incoming CO line was
detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID port.
Replace the circ uit pack.
Continued on next page
Error type Enter error type, or blank
Error List active-alarms, errors, or cleared-errors
Interval h(our), d(ay), w(eek), m(onth), a(ll)
From:/To: Specify time interval by da te and time
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1008 DID-TRK 35 FAIL 61472