DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-437CO-TRK (Analog CO Trunk)
9
Table 9-182. TEST #3 CO Demand Diagnostic Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status t runk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port was seized by a user for a valid c all.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status t runk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005 ABORT Test inapplic ab le to present configuration. This is a normal condition.
1018 AB ORT Test has been disabled vi a administration.
1. For this test to run, the Maintenance Tests? field on the trunk group
form must be set to n. The form is accessed with the change trunk-group
grp# command.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page