DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1548SVC-SLOT (Service Slot)
9
SVC-SLOT (Service Slot)
The Service Slot maintenance object detec ts the insertion of an invalid circ uit
pack a dedic ated SERVICE slot. The SERVICE slot is the leftmost slot in the
J58890BB Port Carrier, and is identified as slot location "00" in all commands,
field entries, and disp lays on the management terminal.
Since this slot does not provide tip and ring connectiv ity to the wall field, only the
following circuit p acks are allowed:
TN744 Call Classifier
TN750 Integrated Announcement
TN771 Maintenance/Test
TN725 Speech Synthesizer
TN433 Speech Synthesizer
TN457 Speech Synthesizer
TN748 Tone Detector
TN420 Tone Detector
TN755 Neon Power Unit
A MINOR alarm is generated aga inst the Service Slot maintenance object when a
circuit pack with a type other than that listed above is inser ted in a SERVICE slot.
The Service Slot maintenance object name is used instead of the maintenance
object name for the illegal c ircuit pack to p revent any attempt to assign a port to
an illegal circuit p ack physically inserte d in the SERVICE slot.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
SVC-SLOT MINOR none Servic e Slot