DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-79ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Aux Data 40977 indicates that no terminal equipment was connec ted
when ringing was attempted . Run the short test via the test port
UUCSSpp command, and follow the p rocedure for the results of Test #48.
b. This is a software audit error that does not indic ate any hardware
malfunction. Run Short Test Sequence and investigate errors (if any).
c. This error type indicates that the c ircuit pack has b een removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
d. Test #48 may cause some terminal equipment to ring briefly during d aily
maintenance. If this ringing is disturbing the c ustomer or the terminal
equipment, it should b e disabled vi a the change station extension
command. However, on some releases of the soft ware, this will disable
Tests #6, 47, and 35 as well as Test #48.
e. Test #47 may cause a false alarm when the port is connected to
off-premises equipment, some non-voic e terminal equipment , and some
loop equipment. If this c auses a false alarm, then disab le the test by
changing the Tests field of the change station command to ‘‘no.’’
f. Refer to ‘‘XXX- BD (Co mmon Port Ci rcui t Pac k)’’ M ainte nanc e
documentation.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table belo w when
inspecting errors in the sys tem. By clearing error cod es associated with the
Battery Feed Test
, for example, you may also clear errors g enerated from other
tests in the testing sequenc e.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Battery Feed Test (#35) X X ND
Station Present Test (#48) X X ND
NPE Crosstalk Test (#6) X ND
Loop Around and Conference Test (#47) X ND
Station Status and Translation Audits and
Updates Test (#36) XXND