DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-985MAINT (EPN Maintenance Circuit Pack)
9
Error Log Entries and Test to Clear Values
Notes:
a. A value of 0 indicates that PNC-A (and therefore, the Expan sion Interface
circuit pack loc ated on PNC-A) was active when this error occ urred. A
value of 1 indicates that PNC-B (and therefore, the Expa nsion Interface
circuit pack loc ated on PNC-B) was active when this error occ urred. To
clear this problem, make sure the Ac tive PNC is the same as that
indicated b y the Aux Value.
b. Multiple values can ap pear in the Aux Data field. There will be other errors
in the log if there is a real problem. Use th ese other errors to troubleshoot
the problem.
c. The serial link between the Expansion Interfac e circuit pac k in the A
carrier and the EPN Maintenance circ uit pack is defec tive.
Table 9-377. EPN Maintenance Circuit Pack Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test maintenance sh r 1
1(a) 0
1 EPN Maintenance Circuit
Pack Reset Test (#306) MINOR ON test maint enance l
513(a) 0
1 MGR I Channel Loop
Test (#228) MINOR ON test maint enance sh r 3
769(b) Any Sanity Handshake Test
(#106)
1537(a) 0
1Sanity Maze Test (#303) MINOR ON test maintenance sh r 3
2561(a) 0
1 Sanity Handshake Test
(#106) MINOR ON test mainte nance sh r 3
2817(a) 0(b)
1Serial Channel Loop
Test (#229) MINOR ON test mainte nance sh r 3
3329(c) Any Serial Link Test (#337) MINOR/
WARNING 2
2. Major and Minor alarms may b e downgraded to Warning alarms based on the value used in the
set options command.
OFF test maintenanc e sh r 3
3585(d) Any Serial Link Test (#337) MINOR/
WARNING 2OFF test maintenanc e sh r 3