DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-898H-ADAPTR (MSS Host Adapter)
9
Disk LED test failed.
Processor bus dual por t RAM test failed.
Processor bus IO registers test failed.
External host adapter loop around failed.
Illegal SCSI target controller requested .
Interrupt during p rocessor bus acc ess.
Bus timeout during proc essor bus acc ess.
Parity error during processor b us access.
Error Detection and Correc tion (EDC) error during processor b us access.
Table 9-343. TEST #822 Host Adapter Read and Clear Firmware
Error Counters Test
Error
Code Test
Result Description/ Recommendation
1311 ABORT Could not read the firmware error counters
1. Retry the command at 1-minute intervals a maximum of 5 retries.
1316 ABORT Could not allocate the Mass Storage System to run this test. Other application
software may be using it or background maintenance tests may be running.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2. If the test continues to abort, verify that the daily translation-save operation
is not in progress (issue the display system-parameters maintenance
command to display the time for scheduled maintenance and the "y/n"
option for saving translation daily).
1335 ABORT Could not run the test on the Standby SPE—Duplication not administered.
1. Ref er to “ STBY-SPE”.
2. Administer standby present.
1338 ABORT Could not run the test on the Standby SPE—Interchange pending.
1. Ref er to “ STBY-SPE”.
2. Af ter in terch ange occu rs, ru n test on new a ctiv e SPE.
1339 ABORT Could not run the test on the Standby SPE—Handshake down.
1. Ref er to “ STBY-SPE”.
2. When the standby is restored to service (use status spe to determine
state of standby) retry the command.
1347 ABORT Could not run the test on the Standby SPE—Refresh not complete.
1. When the standby is restored to service (use status spe to determine
state of standby) retry the command.
Continued on next page