DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-328test data-module
8
The test customer-alarm c ommand performs hard ware diagnostic tests on the
lead s of th e SYSAM or EPN Main tenan ce c ircu it pa ck in a sp ecif ied c abi net.
These leads are connected to customer equipment and provide a means of
alerting the system administrator and INADS when that equipment fails. The
alarm is activated when a relay on the c onnected equip ment is closed for 1
minute.
The cabinet default is 1. The carrier need s be specified only for PPNs with
duplicated SPEs.
test data-module
test data-module extension [short | long] [repeat # | clear] [schedule]
The test data-module c ommand performs hardware d iagnostic tests on a d ata
module or a data channel. Test results are determined by the interface to the
digital switch-d ata line port, digital line port, or network control d ata channel.
test disk
test disk [C] [short | long] [repeat # | clear] [schedule]
The test disk command performs a series of tests on the d isk circuit pac k and
the disk media itself. The cab inet is always 1 and need not b e entered. Carrier a
or b m ust b e spe cif ied o nly fo r dup lic ated SPEs. Thi s com mand will a bor t if an y
other MSS operation has already begun.
Failure of the disk test may result in the disk being taken out of service. In this
state, access to the disk b y all system software except maint enance is blocked .
When the host-adapter is taken out of servic e due to test or reset failures and
becomes uninstalled, th e disk is also placed in the uninstalled state and all
access by system software, mainte nance tests, commands (inc luding resets) is
blocked.
test ds1-facility
test ds1-facility UUCSSf [short | long | external loopback] [repeat #]
[schedule]
The test ds1-facility command performs a series of tests on the sp ecified facility.
Each individual test will exerc ise diagnostics o n the facility and then return
results of the test along with any possible error codes. The long test is
destructive and is not allow ed unless the facility has bee n busied out.