9-522DIOD-DS1 (DS1 DIOD Trunk)
9
f. Error Type 513The DS1 Interface circuit pack d etects a hardware fault.
Aux Data 57393 indicates b elated external release on PBX disconnect.
g. Error Type 769The DS1 Interface circuit pack detec ts a hardware fault.
The Aux Data field contains the following error type:57484, fault is
detected on tip /ring.
h. The DS1Interface circuit pack d etects a hardware fault, and the A ux Data
field contains the following error type: 51200, port is unavailab le. Run the
Dial Tone Test (#314) and follow proced ures.
i. Error Type 1793DS1 Interface circuit pack is out-of-servic e. Look for
UDS1-BD errors in the Hardware Error Log if the port is on a TN464 UDS1
board. Refer to "UDS1-BD (UDS1 Interface Circuit Pack)" (DS1 Trunk
Circuit Pack) for details
j. Error Type 2049—With the following Aux Data:
Aux Data 57473—Rotary dial rate below 8 p ulses per second.
Aux Data 57474—Rotary dial rate above 12 pulses per second.
Aux Data 57475Rotary Dial interdigit time is too short.
The DS1 interface circuit pack d etects a hardware error on the DS1 DIOD
trunk. The trunk can not communicate with the far-end because it is
unable to interpret dig its sent from the far-end switch. Chec k with the
far-end switch or Operatin g Company for proper trunk c onnection.
k. Error Type 2305—Recorder message, tr unk co uld not be seize d (Aux Data
50944). Run Test #314 and follow the outlined procedures.
l. Error Type 2562Retry Failure error. This error is logged only. It is not a
hardware failure and hence do es not start any testing or generate any
alarms. This error comes from call proc essing and is generated when a
second attempt (retry) to s eize an outgoing trunk fails.
m. Error Type 2817Glare error. This error is logged only. It is not a hardware
failure and hence does not star t any testing or generate any alarms. This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end . Attempt to place the c all again. If the error
persists, execute the Dial Tone Seizure Test (#314) and follow those
procedures.
n. Error Type 3840Port Audit and Update Test (#36) failed due to an
internal system error. Enter the status trunk command to verify the status
of the trunk. If the trunk is out-of-service, then enter the r elease trunk
command to put it b ack into in-service. Retry the test command .