DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-932ISDN-PLK (ISDN-PRI Signaling Link Port)
9
TN464C/D UDS1 Interface circuit pac k (UDS1-BD) and the packet bu s
(PKT-BUS).
Error Log Entries and Test to Clear Values
Notes:
a. The D-channel is demand b usied out. No calls can b e made over this
D-channel.
b. This Error Type indicates that the circuit pac k has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. Link error. This error occurs when the p ort receives an invalid frame over
the D-channel. This error normally indicates an off-board problem usually
related to transmission errors on the DS1 facility. Execute list
measurements ds1-log for the UDS1 TN464 circuit pack on wh ich the
D-channel resides. If the UDS1 is reporting some errors, then the DS1
facility has experienc ed transmission problems whic h could have cau sed
the ISDN-LNK to report a Link Error.
Table 9-358. ISDN-PRI Signaling Link Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port
UUCSSpp
2
2. pp is 24 for 24-channel interfaces and 16 for 32-channel interfaces.
18 (a) 0 b usyout port
UUCSSpp
2
WARNING OFF release port
UUCSSpp
2
130 (b) None WARNING ON test port
UUCSSpp
2
1537 (c) 46210 WARNING OFF
1793 (d) test board UUCSS l
3585 (e) 46222 MINOR ON
3841 (f) 46211
3842 (g) 46223
3843 (h) Signaling Port LAN
Loopback test
(#939)
test port
UUCSSpp
2
l