Maintenance Object Repair Procedures
9-1609SYSAM (Circuit Pack)
9
SYSAM Refresh Test (#912)
This test checks the current state of the Alarm Panel LEDs on the SYSAM cir cuit
pack and attemp ts to resynchronize them to reflect the current alarm le vels in the
system. Any discrepanc ies are resolved by chang ing the Alarm Panel LEDs to
what m ainte nanc e bel ieves the a larm l evels shoul d b e. The SYSAM Refres h Test
runs only in G3r V1 software loads preced ing Release 6.0. Newer software has
replaced the SYSAM Refresh Test with the External Modem Present Test (
both
use the Test #912 number).
FAIL The SYSAM did not respond to the sanity handshake query.
1. Run the test maintenance 1a|b long command. The terminal login drops,
and you must login again.
2. If test continues to fail, replace the SYSAM circuit pack at the earliest
convenience.
3. Retry the command.
4. Replace the SYSAM circuit pack. To replace the SYSAM circuit pack, refer
to ‘‘Repl acin g SPE Circ uit Pa cks’’ in Chapter 5.
PASS The SYSAM did respond to the sanity handshake query.
1. Examine other SYSAM tests for errors.
Table 9-608. Test #912 SYSAM Refresh Test
Error
Code Test
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
1318
1335
2029
2033
2500
ABORT Internal system error
1. Retry the command.
Continued on next page
Table 9-607. Test #911 Sanity Handshake Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page