DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1808TSC-ADM (Administered Temporary Signaling Connections)
9
The two administration commands for ADM TSCs are as follows:
add signaling group number
change signaling group number
The two maintenance commands for ADM TSCs are as follows:
test tsc-administered signaling group number [/tsc index]
status tsc-administered signaling group number [/tsc ind ex]
Error Log Entries and Test to Clear Values
Note:
a. There is no Test to Clear Value for error types 3840-3967. These error
types provide the following additional data that may p rove useful when
tracking down p roblems.
Any of these errors indicates that a TSC Heartbeat Inquiry Test was run on
an active far-end Administe red TSC from the switch. Upon receiving the
heartbeat message, the network c ommunicated that the call was unable
to complete. As a result, the error was logg ed. Check the signal ing group
status of the D-channel or D-channel p air via the status signaling-group
<group> command for the Ad ministered TSC. Check the status of the
Administered TSC via the status tsc-administered command. Als o check
the administration of the Administered TSC on the switch.
This error may only be affecting servic e for some DCS customers. Upon
receipt of this error cond ition, the switch will tear down and re-establish
the ADM TSC within 20 minutes.
Table 9-675. ADM TSC Error Log Entries
Error Type Aux Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
3840-3967 (a) tsc index # test tsc -administered