DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-329BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]
9
Clear Error Counters Test (#270)
This test is not an actual test in the strict sense of the word . There are various
error counters associated with e ach
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT. This test clears those
counters and trigg ers the auditing of Terminal Endpoint Identifier (TEI) values and
layer 3 reinitialization. This test is used only to send messages to the
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT and, therefore, should
neither abort nor fail
Table 9-146. TEST #625 Receive FIFO Overflow Error
Counter Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of five times, reset the circuit
pack via the busyout board PCSS and reset board PCSS commands.
2. If the test aborts again, replace the circuit pac k.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, escalate the problem.
value FAIL The BRI-LINE circuit pack is still detecting errors of this type. The Error Code
field contains the value of this counter.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, run the Long Test Sequence and pay
particular attention to the Loop Around Tests (#618 and #619). See the
repair procedures for the executed test if it fails. Otherwise, go to the
next step.
3. Replace the circuit pack.
PASS The Receive FIFO Overflow error counter was read correctly and has a value
of 0.
Continued on next page