DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-17ADX8D-PT (AUDIX Digital Port)
9
e. The circuit pack is ad ministered but not physic ally installed. The alarm will
clear when a circuit p ack is inserted.
f. The circuit pack has b een removed or has been insane for more than
21-minutes. To clear the error, reinsert or replace the AUDIX circuit p ack
(see pcaution at the beg inning of this section).
g. Something is interfering with transm itting to the voice port. This is usually
an on-board problem a nd can be ignored if no user complaints are
received .
h. AUDIX is not available to the switch, possib ly due to a busyout on the
AUDIX system. Check out the AUDIX system referring
DEFINITY AUDIX System Maintenance
, 585-300-110, if necessary.
i. An in-line maintenance error has genera ted an off-board warning due to
some problem with the link to the voic e port. This can be ig nored if no user
complaints are received . If the problem persists, repl ace the circuit pac k
(see precaution at the beg inning of this section). Onc e the problem is
resolved, the alarm is retired after a ce rtain period of time.
j. The link between the circuit pac k and the voice por t is successfully reset.
No craft action is necessar y.
k. No voice ports are connec ted to the DEFINITY AUDIX circuit pack. No
maintenance action is required .
l. The message buffer in the circuit p ack is full.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below when you a re
inspecting errors in the sys tem. By clearing error codes associated with the
Voice and Control Channel Local Looparound Test
for example, you may also
clear errors generated from other tests in the testing sequence.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Voice and Control Channel Local Loop around
Test (# 13) XND
NPE Crosstalk Test (#9) X ND