DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-146list measurements ds1
8
Parameters
Examples
list measurements ds1 2a18
list measurements ds1-log 2e01a
list measurements ds1-facility summary 2e01d schedule
Output
The following field descriptions pertain to the summary reports accessed by list
measurements ds1 and list measurements ds1-facility summary.
UUCSS The location of a DS1 circuit pack.
UUCSS The location of a DS1 converter facility where
UUCSS
is the location of
the circuit pac k and
f
is a letter (a-d) designatin g one of the four DS1
facilities.
Counted Since: The start time and date when the associ ated measurement
counters were cleared, or when t he DS1C circuit pack or fac ility
was administered.
Number of
Seconds Elapsed
Into Current
15-min
Interval:
The number of seconds from the b eginning of the curren t
15-minute interval. This field has a value from 0 to 900.
Total of Valid
15-min
Intervals in
Past 24-hr
Period:
The total number of 15-minute intervals in the past 24-hour period
that contain valid data . This field has a value from 0 to 96.
Category The following four fields report da ta form the error counters.
Errored Seconds The value of the errored seconds c ounter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if
the data for the 15-minute interval is invalid .
Bursty Err Secs The value of the bursty errored second s counter for the spec ified
15-minute interval. This field has a value from 0 to 900 or N/A if
the data for the 15-minute interval is invalid .
Severely Err
Secs The value of the severely errored second s counter for the
specified 15-minute int erval. This field has a value from 0 to 900
or N/A if the data for the 15-minute interval is inva lid.