Maintenance Commands
8-335test eda-external-device-alrm
8
The following display shows a typ ical result when test duplication-interface is
entere d and A is t he ac tive c arrie r of a d upli cate d SPE syst em.
test eda-external-device-alrm
test eda-external-device-alrm all | physical location [repeat number | clear][
schedule]
This test will perform hardware diag nostic tests on an individ ual
external-device-alarm p ort or on all external-device-alarm p orts.
The test eda-external-device-alrm command performs a hard ware diagnostic
test on all administered external de vice alarms if all is entered. If an administered
external device alarm p ort is entered, the test external-devic e-alarm command
performs a hardware diag nostic test on that port. The test PASSES if the external
device is not reporting an external device alarm and FAILS if the external device
is reporting an external d evice alarm. If the technician specifies the port it must
be administered as an externa l device alarm port on a mainte nance board or on
an analog line port car rier board.
Defaults
The default for this command is a rep eat of 1.
Test No. The number of the test being executed.
Result An indicator as to whether the test failed , passed or was aborted .
Error Code A numerical descrip tion of why the test failed or was aborted .
test duplication-interface
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B DUPINT 979 PASS
01A DUP-CHL 980 PASS
01A DUP-CHL 874 PASS
01A DUP-CHL 875 PASS
01A DUP-CHL 876 PASS
Command Successfully Completed